Cl2 gas leak detector-Cl2 sensor & Analyzer-portable

Portable Cl2 sensors are used in gas storage leakage monitoring,
Cl2 gas leak detector-Cl2 sensor & Analyzer-portable

Cl2 gas leak detector-Cl2 sensor & Analyzer-portable

Table of Contents

Portable Cl2 sensors are used in gas storage leakage monitoring, drug factory, food factory, hospital gas disinfection residue detection, electrostatic precipitator, gas generator, air purifier, gas leakage, indoor air gas detection scene.

Features:

(1) Lightweight body with one hand
The Cl2 gas detector, the body adopts ABS shell, it feels comfortable, light and portable;
(2) High-quality sensor, high-sensitivity probe
Responsive and fast response|Accurate measurement, response time ≤30s; accuracy ≤3%;
(3) 200,000 data storage/large capacity
One-click export/fast and convenient, you can enter the menu to view, and you can browse/delete records;
(4) Lithium battery power supply, long-lasting battery life
Rechargeable lithium battery, support mobile power, large battery capacity, long standby time;
(5) Principles of mechanics and humanized design
The anti-slip design is based on the principle of human mechanics to ensure product sensitivity and accuracy.
Enhance the comfort of the human body and conform to the operating habits of the human body;
(6) High-definition display
IPS color screen interface, 320*240 resolution, intuitive display;
(7) Three-proof design
The equipment adopts ABS engineering plastics, and the shell is waterproof, dustproof and explosion-proof;
(8) Over-limit multiple alarm function
When the detected gas is more than the set gas value, the sensor will turn on the light alarm and the high-decibel buzzer will beep.
The instrument is marked red to remind in time, and the safety is high.


Details:
Application:

The Cl2 gas detectorare used in gas storage leakage monitoring, drug factory, food factory, hospital gas disinfection residue detection, electrostatic precipitator, gas generator, air purifier, gas leakage, indoor air gas detection scene.


Technical Parameters:
Parameter nameParameter content
Measurement methodElectrochemistry
Charging time≤8H (standard configuration)
Display error≤±3%F.S
Explosion-proof markEXIA II CT6
Recovery Time≤30S
Protection levelIP65
Response timeT90<30s
Working humidity<95%RH non-condensing
Linearity≤ ± 2
Repeatability≤ ± 2
Operating temperature-20°C~ 50°C
Power supply3.6V DC, 1500mAh (standard) lithium battery
Communication methodUSB (charging and communication)
Data storageWithout storage function by default, 150000 and 200000
data storage functions can be customized

Related Reading

Contact Us

Adress: No. 221, Huoju Road, Weihai City, Shandong Province, China
Email: jxiotdz@gmail.com
Whatsapp : +86 155 8830 2704